In the <Journey Editor> I started a journey by insert blocks as now shown in pos 6 to 12 see image journey_editor and the train run perfect as also expected.
Then after some days I add some extra tours shown i position 1 to 5, see image journey_editor.
When starting a tour from Route-sequence Navigator the train start at pos 1 and stop at pos 5.
Position 6 to 12 is never executed, some tip what done incorrect or what cause this issue?
Rgs
Kjell Ivar
  • Win-Digipet-Version:
    2021.2d Premium Editon
  • Anlagenkonfiguration:
    Marklin, CS3+, HSI-88-USB
  • Rechnerkonfiguration:
    Win10

Markus Herzog

Hi Kjell,

it is one of the principle of a route sequence, that it will be terminated when it reaches its destination contact. An the destination contact/trainnumber display is defined by the destination of the last row in the first column. This is a principle since the introduction of these sequences in 2004.

In your case contact 004. Any now when you row 05 has been executed the program will see "ah destination contact 004 has been reached". This principle is necessary because alternative ways within such a sequence can have different lengths and thus it is not always possible, that the last row of a sequence will be reached and because of this any prior arrival at the destination contact number will end the route.

Regards
Markus
  • Win-Digipet-Version:
    WDP 2025.x Beta
  • Anlagenkonfiguration:
    3-Leiter Anlage, Rollendes Material Märklin/Roco/Brawa/Mehano, Fahren: DCC, m3 via Tams MC, Schalten/Melden: Selectrix, BiDiB, Motorola (nur wenige Sonderaufgaben)
  • Rechnerkonfiguration:
    Intel i7

kiv@vftronic.no

Hello thanks for info
That is ok, and now I know why, and workaround is no problem.
Not everything is easy to find in the User manual, and my knowledge still growing.
Rgs Kjell Ivar