Hello Bernd,

 Is there anything I can do, I would really try WDP  :'(

Markus Herzog

Hello,

the inputs of the second detector are reported to the program but not assigned to any module (text also states "unassigned").
In the edit mode click with the mouse button on menu button of the Loconet box and select the menu line for creating a new module. No assign the input number 17 to 32 to a new module and press OK.

Now you can assign feedback contact numbers.

This intermediate step is necessary because in the loconet protocol there is no way to detect feedback modules "as block". The program only see a bunch of report input numbers.

Regards
Markus